Plastic Pipe shall be supported at every _______________meter interval.
Horizontal support for hub less or compression gasket joints must be in every.
For Cast iron pipe exceed 1.5 mts length, it may be supported at not more than ___meters interval.
Lead Pipe shall be supported at an interval not exceeding_________mts at the center with rigid Vertical back up.
Cast Iron pipe in horizontal position must be supported not more than _________ mts interval.
Horizontal support for within Hub or joint of Cast iron pipe must be place at________mts to maintain alignment and sagging.
Vertical Cast Iron Pipe shall be supported in every_________or closer
Copper Tubing – shall be supported at each storey or at maximum intervals of ______ meters on center.
All shower receptors shall be tested for ____________by filling with water to the level of the rough threshold. The test plug shall be so placed that both upper and under sides of the sub-pan shall be subjected to the test at the point where it is clamped to the drain.
Horizontal support for copper tubing shall be supported at approximately _________mts interval for piping 38mm diameter & smaller and ___________mts for piping larger than 51mm diameter.
Devices for heating and storing water shall be so designed and installed as to prevent dangers from through overheating.
Maximum depth of a septic tank as per RPCP.
Plumbing shall be designed and adjusted to use the ____________ quantity of water consistent with proper performance and cleaning.
For soil having questionable absorption capacity a ________ test is required.
Minimum capacity of digestive chamber of a septic tank as per RPCP.
All premises intended for human use or habitation shall be provided with a supply of pure and wholesome water, neither connected to unsafe water supply nor subject to backflow or _____.
The minimum distance required between a Septic Tank and Water supply wells.
Basic principles listed in Revised Plumbing Code of 1999 was based on what Section of RA 1378?
Each fixture directly connected to the drainage system shall be equipped with a ____________-sealed trap.
Pressure Vacuum Breaker Backflow Prevention Assembly (PVB)- consists of a loaded _______ inlet valve, an internally load check valve, two properly located test cocks and two isolation gate valves.
The Following are author of Plumbing Engineering Bill in Senate and Congress Except:
What is the minimum airgap for water distribution for lavatories with an effective opening not greater than 13 mm diameter and affected by side walls?
Date of first amendments of National Plumbing Code of the Philippines.
No excavation for a leach line or leach bed shall extend within ____m of the water table nor to a depth where sewage may contaminate the underground water stratum that is usable for domestic purposes.
Where leaching beds are permitted in lieu of trenches, the area of each such bed shall at least ________% greater than the tubular requirements for trenches.
If septic tank has over 6 cu mts capacity, the secondary compartment must be at least____ft.
To attempt to ________ falsely or maliciously, directly or indirectly, the professional reputation, prospects, or business of another Master Plumber.
Maximum depth of a septic tank as per RPCP.
Minimum depth of a septic tank as per Fajardo book.
Date of signing by Pres Joseph Estrada of Revised Plumbing Code of 1999?
Material used in Galvanized Steel pipe.
Minimum dimension of Septic tank manhole.
What type of Cast Iron Pipe generally used for underground installation and considered extra duty pipe?
Which of the following not part Cast Iron varieties?
Galvanized Steel pipe easily corroded by_______________and acid water.
Galvanized Steel pipe deteriorates faster when used as______________supply line.
Limit of the use of Cast iron Pipe.
Most expensive type of pipe.
The minimum wall thickness of any steel tank shall be No. U.S. gauge and each such tank shall be protected from corrosion, both externally and internally, by an approved bituminous coating or by other acceptable means.
Structural Design capacity of Septic tank cover as per RPCP.
Galvanized Wrought Iron is more resistant to ______waste than the steel pipe.
The cheapest among sewer type pipes?
Acid resistant Cast Iron is made of what?
Brass is composed of ____%zinc and ____%copper.
Upon completion of a section or of the entire hot and cold-water supply systems, it shall be tested and proved tight under a water pressure not less than the working pressure under which it is to be used plus ________%.
In what type of structure Asbestos Pipe best suited?
Where can asbestos pipe be used?
What is the difference in invert elevation between inlet and out pipe of a Septic Tank?
When the length of first compartment exceed _____ft. additional manhole must be provided over the wall of baffles.
Composition of Asbestos Pipe.